			Uses:The device uses physical method to achieve disinfection and 
			sterilization. It takes advantage of high-temperature and hot air to 
			cause intoxication on microbial oxidation, protein denaturation, and 
			electrolyte concentration. By disinfection principle, it destroys 
			protoplasmic cell to kill all the microorganisms in a certain period 
			of heating time.
 Characteristics:
 1. Cold rolling steel electrostatic spraying exterior.
 2. Stainless steel inner chamber; with the semicircular arcs at 
			corners for easy cleaning. The space between the shelves in the 
			chamber is adjustable. The two sides heating air passage and bottom 
			heating cover can be fast assembly and disassembly.
 3. PID Microprocessor digital controller has the function of timing, 
			lack of water and over-temperature protection.
 4. The special air forced heat radiation construction ensure the low 
			noise fan temperature less than 50°C. Turbine centrifugal fan ensure 
			the fan can be used more longer time.
 5. High quality heat isolation door with wide hollow tempered glass 
			observation window, adjustable air-tight buckle lock and silicon 
			rubber seal.
 
			BE function type has the following 
			characteristics other than the above functions: 
			1. With adjustor to adjust the fan 
			speed, the user can choose use the fan and adjust the speed ensure 
			the high temperature evenness, or not use the fan to avoid the 
			powder or other small samples move in the inner chamber.2. Large LCD screen shows the multiple data, has the function of 
			timing and over-temperature protection.
 3. Independent audible and visible temperature-timing alarm system, 
			cut off the power when over-temperature limited automatic ensures 
			experiments run safety and no accident would happen.
 4. Can be connected the RS485 connector and software to download and 
			save all the data via RS485 into computer. 
			(Optional Accessories)
 Optional accessories:
 a. Desk printer
 b. Change the far infrared heating tube becomes to the far infrared 
			Hot-air Sterilizer
 
			Note: model SRX230 has no function of speed 
			adjustment.  
			B series are standard 
			type with LED screen; BE series are function type with LCD screen.Main parameters
 
				
					
						| 
						
						Model | 
						
						SRX30B/BE  | 
						
						SRX45B/BE  | 
						
						SRX65B/BE  | 
						
						SRX85B/BE  | 
						
						SRX125B/BE  | 
						
						 SRX230B/BE  |  
						| 
						
						Voltage | 
						
						220V/50Hz |  
						| 
						
						Tem. Range (°C) | 
						
						RT+5~300°C |  
						| 
						
						Tem. Motion (°C) | 
						
						+/-1°C |  
						| 
						
						Tem. Resolution Ratio (°C) | 
						
						0.1°C |  
						| 
						
						Ambient tem. (°C) | 
						
						5-40°C |  
						| 
						
						Heating power (w) | 
						
						0.8 | 
						
						1.2 | 
						
						1.6 | 
						
						1.8 | 
						
						2.3 | 
						
						3 |  
						| 
						
						Inner Chamber Size (mm) | 
						
						310*310*310 | 
						
						350*350*350 | 
						
						400*360*450 | 
						
						450*420*450 | 
						
						500*450*550 | 
						
						600*500*750 |  
						| 
						
						Exterior Size (mm) | 
						
						400*510*695 | 
						
						500*550*735 | 
						
						550*550*840 | 
						
						590*630*830 | 
						
						636*680*915 | 
						
						730*670*1220 |  
						| 
						
						Packing Size (mm) | 
						
						610*540*830 | 
						
						660*590*875 | 
						
						670*640*970 | 
						
						680*720*920 | 
						
						760*750*1070 | 
						
						900*800*1350 |  
						| 
						
						Load per rack (Kg) | 
						
						15/kg 2 for standard configuration |  
						| 
						
						N.W. (Kg) | 
						
						39 | 
						
						42 | 
						
						48 | 
						
						52 | 
						
						58 | 
						
						70 |  
						| 
						
						G.W. (Kg) | 
						
						52 | 
						
						55 | 
						
						61 | 
						
						65 | 
						
						73 | 
						
						115 |  
						| 
						
						Timing range | 
						
						1-9999min |  |