AZ8716 AT A GLANCE
-INSTANTLY CALCULATE DP (DEW POINT) AND (WB) WEB BULB TEMPERATURE .
-EASY TO READ T1, T2, T1-T2 .
-ACCURATE TO GET STABLE READING FOR THE DIFFERENCE FOR SURFACE (T2)AND DEW POINT TO THE ENVIRONMENTS OF PROTECTIVE COATING / PAINTING FIELD .
-UNIQUE DESIGN ON SENSOR PROTECTION .
-ROTRONIC HUMIDITY SENSOR-CAPACITANCE TYPE .
-OPTIONAL EXTERNAL PENETRATE PROBE FOR CHECKING FOOD QUALITY .

 

FEATURE

Besides main functions and features of 8706 , the meter triple combination displays:
Humidity / T1, T2, or Humidity T1-T2, or
Humidity / Dew Point and Wet Bulb, or
Humidity / T2 (external sensor) and Dew Point, or
Humidity/Dew Point and Delta T (T2-DP) . . .

Quick to get without whirling the meter or refer to the chart need the reading of Wet Bulb / Dry Bulb and Dew Point temperature in seconds .

ºC or ºF switchable with 0 .1ºC or 0 .1 ºF resolution, battery low indication, self-calibration available for longer life by salt solution .

Humidity sensor: Rotronic electronic capacitance type .

For monitoring Food Safety and preparing HACCP documentation by sensing external temperature from meats, liquids, soft foods .

 

SPECIFICATION
Temp . range : -20~+50ºC(- 4~+122ºF)
RH% range : 0~100%RH
Wet blub range : -21 .6~50 .0ºC(-6 .9~122ºF)
Dew point range : -78 .7~50 .0ºC(-109 .7~122ºF)
External temp . range : -20~+70ºC(- 4~+158ºF)
Accuracy : RH% : \3% at 25ºC Temperature : \1ºF(0 .6ºC)
Pocket size : 24 .7(H) x 48 .4(W) x 178 .5mm(L)
Response time : 60 seconds typical
Extension cable length : 116cm (with phone jack 2 .5mm)
Probe (with handle) : 15cm(approx)
Package: Gift box, Battery, Manual .

Packing: 50PCS/CTN, CTN SIZE: 60*50*60CM, G.W: 30KGS, VOLUME WEIGHT: 36KGS
Power : 2x1 .5V AAA battery
Optional accessory : External temp . probe VZ87P6 AZ, Humidity calibration salt solution(HR33, HR75)

AZ8726 AT A GLANCE
-FEATURES MEMORIES STORING AND RECALLING FOR (WB) WEB BULB OR DP( DEW POINT) TMP, DELTA T .
-EASY TO GET T2 , T1-AIR TEMPERATURE .
-BACKLIGHT IN DARK AREA .
-REAL TIME CLOCK FOR EACH MEMORY DATA .
-TUNABLE CAP TO PROTECT SENSOR  .
-EASY TO SELF-CALIBRATE BY SALT SOLUTION .
-INFRARED OUTPUT FOR PRINTING WIRELESS TO THE OPTIONAL PRINTER .

FEATURE
Besides the full functions and features of 8716 , An additional features to store 99 data points and recall later for a Max/ Min / Average readings from LCD display .

Quick to get without whirling the meter or refer to the chart need the reading of Wet Bulb / Dry Bulb and Dew Point temperature in seconds .

ºC or ºF switchable with 0 .1ºC or 0 .1 ºF resolution , battery low indication, self-calibration available for longer life by salt solution .

Adjustable real time ( H: M: S) and date (Y-M-D) by push button  .

Auto power off by selecting time frame .

Active Backlight by pressing HOLD and power keys for working in dark area  .

ºC or ºF switchable with 0 .1ºC or 0 .1 ºF resolution , battery low indication, self-calibration available for longer life by salt solution .

SPECIFICATION
Temp . range : -20~+50ºC(- 4~+122ºF)
RH% range : 0~100%RH
Wet blub range : -21 .6~50 .0ºC(-6 .9~122ºF)
Dew point range : -78 .7~50 .0ºC(-109 .7~122ºF)
External temp . range : -20~70ºC(- 4~158ºF)
Accuracy : RH% : \3% at 25ºC Temperature : \1ºF(0 .6ºC)
Pocket size : 44(H) x 57(W) x 230mm(L)
Response time : 60 seconds typical
Extension cable length : 116cm (with phone jack 2 .5mm)
Probe (with handle) : 20cm(approx)
Package: Gift box, Battery, Manual .
Power : 4 x 1 .5V AAA batteries
Optional accessory : External temp . probe VZ87P6 AZ, Humidity calibration salt solution (HR33, HR75)

   

AZ8736 / 8746 AT A GLANCE
-K TYPE BEAD SENSOR FOR HIGH TEMPERATURE RANGE .
-RS232 INTERFACE FOR ONLINE LOGGING DATUM .
-EASY TO GET DEW POINT / WET BULB / T1, T2, T1-T2 TEMPERATURE .
-RECORD MEMORIES AND ETRIEVE MINIMUM & MAXIMUM, AVERAGE READINGS FROM MEMORIES DATUM .
-REAL TIME CLOCK FOR EACH MEMORY DATA .
-TRIPOD MOUNTABLE & SENSOR PROTECTIVE MECHANISM .
-INFRARED OUTPUT FOR PRINTING WIRELESS TO THE OPTIONAL PRINTER .

 

FEATURE
Besides the full functions and features of model 8726 , one additional K Type(8736) and two additional K Type(8746) interchangeable probe for an extended temperature range up to -200~1370ºC is added .

RS232 interface for online logging data  . Also enable the user to recall and print wireless via Infrared output to the optional printer (VZ9802AZ - the IrDA data logger printer) for HACCP documentation repaired .

Retrieving Min / Max / Average readings from 99 data points' memories  . Or press button to read Min / Max from the meter powered on .

Using Rotronic capacitor humidity sensor for the accurate
reading ,condensation will not affect meters' accuracy .

3 way to download data and print data .(8746)

SPECIFICATION
Temp . range : -20~+50ºC(- 4~+122ºF)
RH% range : 0~100%RH
Wet blub range : -21 .6~50 .0ºC(-6 .9~122ºF)
Dew point range : -78 .7~50 .0ºC(-109 .7~122ºF)
External temp . range : -20~70ºC(- 4~158ºF)
Accuracy : RH% : \3% at 25ºC Temperature : \1ºF(0 .6ºC)
Pocket size : 44(H) x 57(W) x 230mm(L)
Response time : 60 seconds typical
Extension cable length : 116cm (with phone jack 2 .5mm)
Probe : K Type bead thermocouple (Included)
Package: Gift box, Battery, Manual .
Power : 4 x 1 .5V AAA batteries
Optional accessory : External K Bead sensor (VE60A000) and Humidity calibration salt solution(HR33, HR75)

AZ8706 Hygrometer-probe/DP/WBT AT A GLANCE

-DIGITAL SLING PSYCHROMETER TRIPLE DISPLAY WET BLUB & DEW POINT OR TEMPERATURE.

-QUICK TO GET DEW POINT & WET BULB IN 5 SECONDS COVERING ON APPLICATION TO HVAC&R INDUSTRY .

-EASY TO CARRY, POCKET SIZE WITH TUNABLE CAP DESIGN TO PROTECT SENSORS.

-OPTIONAL EXTERNAL PENETRATE PROBE FOR MEASURING FOOD QUALITY.

Please click here for more detail technical information

AZ8708 Pen type Hygrometer-DP/WBT

-READ TEMP / RH SIMULTANEOUSLY.

-CAPACITANCE POLYMER SENSOR! HOLD / MIN / MAX FEATURES.

-MOST ACCURATE RH PEN ON THE MARKET.

 

Specifications(PDF file)

AZ8709 Hygrometer-DP/WBT/CAL

-READ TEMP / RH SIMULTANEOUSLY.

-CAPACITANCE POLYMER SENSOR! HOLD / MIN / MAX FEATURES.

-MOST ACCURATE RH PEN ON THE MARKET.

-EASY SELF-CALIBRATION.

Specifications(PDF file)

AZ8701 Hygrometer

-DISPLAY TEMPERATURE & HUMIDITY

-CAPACITANCE POLYMER SENSOR.HOLD / MIN / MAX FEATURES.

-CONVENIENT POCKET SIZE WITH CAP.

 

 

Specifications(PDF file)

AZ8703 Hygrometer-Dew point

-DISPLAY TEMPERATURE & HUMIDITY.

-CAPACITANCE POLYMER SENSOR.HOLD / MIN / MAX FEATURES.

-DISPLAY DEW POINT.

-CONVENIENT POCKET SIZE WITH CAP.

Specifications(PDF file)

AZ8705 Hygrometer-Dew Point/WBT

-DISPLAY TEMPERATURE & HUMIDITY.

-CAPACITANCE POLYMER SENSOR.HOLD / MIN / MAX FEATURES.

-DISPLAY DEW POINT & WET BULB TEMP.

-CONVENIENT POCKET SIZE WITH CAP.

Specifications(PDF file)

AZ8706N Hygrometer-probe

-DIGITAL SLING PSYCHROMETER

-TRIPLE DISPLAY TEMPERATURE/HUMIDITY/PROBE TEMP. 

-EASY TO CARRY, POCKET SIZE WITH TUNABLE CAP DESIGN TO PROTECT SENSORS.

-OPTIONAL EXTERNAL PENETRATE PROBE FOR MEASURING FOOD QUALITY.

 

Specifications(PDF file)

AZ8711 Hygrometer

-REMOTE PROBE FOR HUMIDITY / TEMP.

-RESISTANCE POLYMER SENSOR.

-RS232 INTERFACE.

 

 

Specifications(PDF file)