PROVA-5601/5637
Clamp-on Ground Resistance Tester
|
|
 |
|
-
Non-Contact Ground
Resistance Measurement
-
No Auxiliary
Electrode Needed
-
Jaw Diameter ¦µ 23 mm
(5601)
-
Jaw Diameter ¦µ 35
mm(5637)
-
0.025 ¨C 1500 Ohm
|
-
0.2mA¨C
30A(5601)0.2mA¨C 35A(5637),True RMS
-
116 Sets of
Memory(5601,5637)
-
Programmable Hi and
Lo Alarm(5601,5637)
-
Programmable Data
Logging (5601,5637)
|
|
|
-
Telecommunication
-
Cable TV system
-
Electrical Power
Plant
|
-
Cellular Phone
System
-
Factory and Facility
-
Gas Station Tank
|
|
 |
¡¡ |
|
Ground
Resistance (Auto range) |
|
Range |
Resolution |
Accuracy of Reading
1, 2 |
|
0.025 - 0.250 ¦¸ |
0.002 ¦¸ |
¡À 1.5% ¡À 0.05 ¦¸ |
|
0.250 - 1.000 ¦¸ |
0.02 ¦¸ |
¡À 1.5% ¡À 0.05 ¦¸ |
|
1.001 - 9.999 ¦¸ |
0.02 ¦¸ |
¡À 1.5% ¡À 0.1 ¦¸ |
|
10.00 - 50.00 ¦¸ |
0.04 ¦¸ |
¡À 2.0% ¡À 0.3 ¦¸ |
|
50.01 - 99.99 ¦¸ |
0.04 ¦¸ |
¡À 2.0% ¡À 0.5 ¦¸ |
|
100.0 - 200.0 ¦¸ |
0.4 ¦¸ |
¡À 3.0% ¡À 1.0 ¦¸ |
|
200.1 - 400.0 ¦¸ |
2 ¦¸ |
¡À 5.0% ¡À 5 ¦¸ |
|
400.1 - 600.0 ¦¸ |
5 ¦¸ |
¡À 10% ¡À 10 ¦¸ |
|
600.1 - 1500 ¦¸ |
20 ¦¸ |
¡À 20% |
|
1 Loop
resistance noninductive, external field <
200 A/m, external electrical field < 1 V/m,
conductor centered.
2 Resistance
Measurement Frequency:
1.667KHz, 3.333KHz(optional) |
|
|
Ground/Leakage Current (Auto range, 50/60
Hz, True RMS, Crest Factor < 3.5)
|
|
Range |
Resolution |
Accuracy of Reading |
|
0.200 - 1.000 mA |
0.001 mA |
¡À 2.0% ¡À 0.05 mA |
|
1.00 - 10.00 mA |
0.01 mA |
¡À 2.0% ¡À 0.03 mA |
|
10.0 - 100.0 mA |
0.1 mA |
¡À 2.0% ¡À 0.3 mA |
|
100 - 1000 mA |
1 mA |
¡À 2.0% ¡À 3 mA |
|
0.20 - 4.00 A |
0.001A |
¡À 2.0% ¡À 0.03A |
|
4.00 - 30.00 A(5601) |
0.01A |
¡À 3.0% ¡À 0.03A |
|
4.00 - 35.00 A(5637) |
0.01A |
¡À 3.0% ¡À 0.03A |
|
|
Accuracy of
Resistance Calibration Plate |
¡À0.5% |
|
Data Logging Capacity |
116 records |
|
Data Logging Interval |
1 to 255 seconds |
|
Conductor Size |
35mm /1.38"(5637),
23mm /0.90"(5600,5601) |
|
Jaw Opening |
38mm /1.49"(5637),
27mm /1.06"(5600,5601) |
|
Battery Type |
9V IEC 6 LR61
(Alkaline) |
|
Display Type |
4 digits 9999 counts
LCD |
|
Overload Indication |
OL |
|
Battery Life |
3000 measurements |
|
Range Selection |
Auto |
|
Power Consumption |
40mA |
|
Sampling Time |
0.5 seconds |
|
Operating Temperature |
0ºC to 50ºC (14ºF to
122ºF ) Operating Humidity: Less than
85% RH |
|
Storage Temperature |
-20ºC to 60ºC (-4ºF
to 122ºF ) Storage Humidity: Less than
75% RH |
|
Dimension( 5637) |
276mm (L) x 100mm(W)
x 47mm(H),10.8" (L) x 3.9"(W)
x 1.9"(H) |
|
Dimension( 5600, 5601
) |
257mm (L) x 100mm(W)
x 47mm(H),10.1" (L) x 3.9"(W)
x 1.9"(H) |
|
Weight( 5637) |
750g/1.65lbs |
|
Weight( 5600, 5601) |
640g/1.41lbs |
|
Accessories |
Resistance
Calibration Plate x 1 |
|
Battery 9V
(Installed) x 1 |
|
Carrying Box x 1 |
|
Users Manual x 1 |
|
|
CM-02/04
Clamp
Meter/Automotive Clamp
|
 |
 |
-
DC/AC 0.01A
Resolution
-
AC/DC
0.01A~200A
-
23mm Jaw
Diameter
-
One Touch
Zero
-
Temperature
and Capacitance
-
Auto Range
V. W .Hz. o C.
-
3 3/4 Digits
(4000 Counts)
-
0~9999
RPM(CM-04)
|
|
 |
|
|
|
|
|
|
AC Voltage (Autorange, Input
Impedance 5M W )
|
|
|
DC Voltage (Auto range,
Overload Protection 800VAC )
|
|
|
Frequency (Hz, Autorange &
Sensitivity selected by range
button) |
|
|
Resistance( W )&Audible
Continuity (Open Circuit Voltage
0.5V): |
|
|
|
|
Resistance( W )(Autorange &
Manual, Open Voltage<=0.5V)
|
|
|
Capacitance (Autorange & Manual)
|
|
|
TEMP K TYPE ºC (Autorange &
Manual, ºF optional):
|
|
|
Conductor Size |
23mm
Diameter |
|
Battery |
1.5V
AA UM3 Battery x 2 |
|
Display |
3
3/4Diguts (4000Counts)
|
|
Range Selection |
Auto
and Manual |
|
Power Consumption |
10mA
(Approx) |
|
Sampling Time |
2Time/sec (Digital) 20Time/sec
(Bar graph) |
|
Operating Temperature |
0 ºC
~ 50 ºC (32 ºF ~122 ºF)
|
|
Operating Humidity |
LESS
than 80% RH |
|
Dimension |
7.2"(L) x 2.5"(W) x 1.4"(H)
183mm(L) x 63.6mm(W) x 35.6mm(H)
|
|
Weight |
190g. (Batteries Included)
|
|
Accessories |
Adaptor (for K-type Thermocouple
and Capacitor) x 1
User Manual x 1
5V Battery x 2
K-type Thermocouple x 1
Carrying Bag x 1 |
|
Option |
RPM
Adaptor(COM04) x 1 |
|
|
|
|